DSP Sine Wave Static UPS 2.5KVA,3.5KVA and 5KVA |
SALIENT FEATURES
- State of the art MOSFET based PWM Technology to increase Crest Factors.
- Auto Sense Intelligent Control Smart Charger.
- Electronic change-over,hence much better reliability.
- Quiet operation of AC motors as well as other inductive loads unlike the noise that emanates from modified Sine Wave Systems.
- Very low Total Harmonic Distortion <3%.
- Fast Changeover ensuring Compatibility with Computers.
- TDR(Time Delay Relay),especially for AC Compressor based applications.
- Main Mode Short Circuit Protection
- Surge load Capacity upto 300%.
- Less Operating Cost as compared to that with online UPS as well as DG Sets.
- Bypass Switch incase of Systems Failure.
- Co,patibility with D.G.Sets.
|

 |
APPLICATIONS
- Suitable for providing alternate power source in corporate offices,BPOs,KPOs etc.
- Supports all office equipements including computer,scanner,printers,fax maxchines etc.
- Provision for emergency & portable power systems.
- Supports air conditioner as well as all compressor based appliances.
- Aids petrol/diesel filing machines.
- As an all rounder it also helps tread mills and other health equipments to run.
- Motor based appliances like water pumps are also supported.
|
Crompton Greaves Limited |
| Description |
2.5KVA |
3.5KVA |
5KVA |
| Back-up Mode |
| Output Wave Form |
Pure Sine Wave |
| Nominal Battery Voltage |
48V DC |
48V DC |
96V DC |
| Output Power Factor |
0.8 |
| No Load O/P Voltage |
220V±5V AC |
| O/P Frequency |
50Hz±1Hz |
| Maximum No load Batt. Current |
1.1A±0.2 A |
| Full Load O/P Current |
8.7A±0.5 A |
11.5A±0.5 A |
17A±0.5 A |
| Total Harmonic Distortion |
<3% |
| Low Battery Indication |
10.5V+/-0.2V DC Per Battery(12V DC Each) |
| Low Batt. Cut off |
10.3V+/-0.2V DC Per Battery(12V DC Each) |
| Mains Mode |
| Max. Charging Current |
10A±1A |
| Full Load O/P Current at Mains Mode |
15A±1A |
17.6A±1A |
25A±1A |
| Boost Charging Voltage |
10.5V+/-0.2V DC Per Battery(12V DC Each) |
| Float Charging Voltage |
13.7V+/-0.2V DC Per Battery(12V DC Each) |
| Noramal Mode |
| Input Voltage Range |
100V to 280V AC±10V AC |
125V to 280V AC±10V AC |
| Change Over Time(mains to inverter) |
<40ms |
| Change Over Time(mains to inverter) |
<25ms |
| UPS Mode |
| Input Voltage Range |
180V to 260V AC±5V AC |
| Change Over Time(mains to inverter) |
<10ms |
| Change Over Time(inv. to mains) |
<10ms |
| Protections |
| Protections |
Output Not Ok,Battery Voltage Low(4 Auto Retries),Over Load(6 Auto Retries) |
| Battery Over Charge,Over Temperature,Short Circuit,Mains MCB Tripped |
| Displays |
| Displays |
Welcome Message,Cpacity,Output Voltage,Output Frequency,Load Percentage |
| Input Voltage and Frequency,Load Percentage,Load Percentage,Battery Charging,Battery Voltage,and All Protections.. |
| Environmental Parameters |
| Operating Temperature |
0-45Deg. |
| Acoustic Noise at 1 Mtr. |
<45 dB. |
| Relative Humidity |
Max 95% non-Condensing |
| Thermal Management |
Integrated Cooling(Fan & Heat Sink) |
| Weight and Dimensions |
| With Packaging LXWXH in mm |
470x440x610 |
470x440x610 |
500x495x660 |
| Without Packaging LXWXH in mm |
310x290x450 |
310x290x450 |
350x300x540 |
| Net Weight |
29Kg |
36Kg |
54Kg |
| Gross Weight |
36Kg |
39Kg |
58Kg |